Part Number Hot Search : 
TPDV625 PIC16F87 00002 LM393AM D74ALVC1 DS9075 N2800 EL817B
Product Description
Full Text Search
 

To Download PST600D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MITSUMI
System Reset PST600
System Reset
Monolithic IC PST600
Outline
This IC operates in a variety of CPU systems and other logic systems by detecting power supply voltage, so that the system can be reset accurately when power is turned on or when power is momentarily cut. PST572 and others perform the same function as does this series, but this IC is a low reset type system resetting IC which follows load current so that circuit current flow increases for ON, and has low current consumption for both ON and OFF.
Features
1. Follows load current so that circuit current flow increases for ON, and has low current consumption for both ON and OFF. No load : ICCL=7A typ.; ICCH=5A typ. 2. Low operating limit voltage 0.65V typ. 3. Hysteresis voltage provided in detection voltage 50mV typ. 4. The following 10 ranks of detection voltages are available. PST600 C : 4.5V typ. H : 3.1V typ. D : 4.2V typ. I : 2.9V typ. E : 3.9V typ. J : 2.7V typ. F : 3.6V typ. K : 2.5V typ. G : 3.3V typ. L : 2.3V typ.
Package
MMP-3A (PST600 M) TO-92A (PST600 ) contains detection voltage rank.
*
Applications
1. Microcomputers, CPU, MPU reset circuits 2. Logic circuit reset circuits 3. Battery voltage check circuits 4. Back-up power supply switching circuits 5. Level detection circuits
Equivalent Circuit
MITSUMI
System Reset PST600
Pin Assignment
1 2 3 1 2 3
VCC GND VOUT
1
3
1 2
VCC GND VOUT
2
3
TO-92A
MMP-3A
Absolute Maximum Ratings
Item Storage temperature Operating temperature Power supply voltage Allowable loss
(Ta=25C) Symbol TSTG TOPR VCC max. Pd Ratings -40~+125 -20~+75 -0.3~10 200 (MMP-3A) 300 (TO-92A) Units C C V mW
Electrical Characteristics
Item
(Ta=25C) (unless otherwise indicated resistance unit is ) Measurement circuit
Symbol
Measurement conditions PST600C PST600D PST600E PST600F RL=470 PST600G VOL < 0.4V = PST600H VCC=H L PST600I PST600J PST600K PST600L RL=470, VCC=L H L RL=470, Ta=-20C~+75C VCC=Vs min. -0.05V, RL=470 VCC=10V IOL=0mA VCC=Vs min. -0.05V IOL=8mA VCC=Vs typ./0.85V, RL= RL=4.7k, CL=100pF 1 RL=4.7k, CL=100pF 1 RL=4.7k, VOL < 0.4V = VCC=Vs min. -0.05V, RL=0 Ta=-20C~+75C, RL=0 2
Min. Typ. Max. Units 4.3 4.0 3.7 3.4 3.1 2.9 2.75 2.55 2.35 2.15 30 4.5 4.2 3.9 3.6 3.3 3.1 2.90 2.70 2.50 2.30 50 0.01 0.3 7 50 5 40 20 0.65 0.4 0.1 14 130 10 80 40 0.85 4.7 4.4 4.1 3.8 3.5 3.3 3.05 2.85 2.65 2.45 100
Detection voltage
Vs
1
V
Hysteresis voltage Detection voltage temperature coefficient Low level output voltage Output leak current Circuit current for ON Circuit current for OFF H transmission delay time L transmission delay time Operating limit voltage Output current 1 for ON Output current 2 for ON
Vs Vs/ T VOL IOH ICCL ICCH tPLH tPHL VopL IOL 1 IOL 2
1 1 1 1 1 1 2 2 1 1 1
mV %/C V A A A S S V mA mA
* *
20 10 8 6
*
* *
1 tPLH : VCC= (Vs typ. -0.4V) 2 VCC=Vs min. -0.15V
(Vs typ.+0.4V), tPLH : VCC= (Vs typ.+0.4V)
(Vs typ.-0.4V)
MITSUMI
System Reset PST600
Measurement Circuit
[1] [2]
VS 4.9 4.1 0V
* The input model is an example of PST600C (MMP-3P).
Characteristics
VCC vs. VOUT
8 7 6 5 Vout 4 (V) 3 2 1 0 0
(PST600C is used as the representative model for characteristics examples.)
VOL vs. Ta
450 400
Ta=-25C Ta=25C Ta=75C 1 2 3 4 5 6 7 8
VOL 350 (mV) 300
250 200 -40 -20 0 20 40 60 80
VCC (V)
Ta
(C)
VS vs. Ta
80 70 60
VS vs. Ta
4.7 4.6
VS 50 (mV)
40 30 20 -40 -20 0 20 40 60 80
VS (V)
4.5 4.4 4.3 4.2 -40 -20 0 20 40 60 80
Ta (C)
Ta(C)
ICCL vs. IOL
100 80 60 40 20 0 0 2 4 6 8 10 12
ICCH vs. Ta
8 7 6 5 4 3 -40 -20 0 20 40 60 80
ICCL (A)
ICCH (A)
IOL (mA)
Ta(C)
MITSUMI
System Reset PST600
IOL vs. Ta
60 50 40 30 20 10 -40 -20 0 20 40 60 80
VOL vs. IOL
500 400
IOL (mA)
VOL (mV)
300 200 100 0 0 2 4 6 8 10 12
Ta (C)
IOL (mA)
ICCL (IOL=0mA) vs. Ta
9 8 7 6 5 4 -40 -20 0 20 40 60 80
ICCL (A)
Ta (C)
Application Circuits
1. Normal hard reset Delay Time (tPLH) ** =CL RL VCC [ln ------------------------ ]+0.040 (mS) VCC- (VS
CPU+0.2)
Vs CPU : CPU, MPU reset threshold voltage CL : F RL : k Voltage : V Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2.
2. Manual Reset
Note : Prevent Manual SW chattering by using RL , CL and Rm. Rm setting conditions are as follows : Rm < 1/20 RL = Note : When VCC line impedance is high,connect a capacitor between IC Pins 1 and 2.
MITSUMI 3. Battery Checker (LED ON for High voltage)
System Reset PST600
Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2.
4. Battery Checker (LED ON for Low voltage)
Note : When VCC line impedance is high, connect a capacitor between IC Pins 1 and 2.